Advanced Search

Indexed by SCI、CA、РЖ、PA、CSA、ZR、etc .

Volume 16 Issue 4
Dec 2005
Turn off MathJax
Article Contents
Jun Yang, Li Li, Aiwu Fan. Seismic Analysis of Shear-Wall Structures with Vertically Installed Dampers. Journal of Earth Science, 2005, 16(4): 349-353.
Citation: Jun Yang, Li Li, Aiwu Fan. Seismic Analysis of Shear-Wall Structures with Vertically Installed Dampers. Journal of Earth Science, 2005, 16(4): 349-353.

Seismic Analysis of Shear-Wall Structures with Vertically Installed Dampers

More Information
  • Corresponding author: Yang Jun, whuci@sohu.com
  • Received Date: 14 May 2005
  • Accepted Date: 29 Aug 2005
  • Shear-wall structures are quite common in seismic areas because of their successful seismic behavior during severe earthquakes.But shear walls are prone to brittle failure.This study proposes a new method of vertically installed dampers (VID) to reduce the vibration in shear-wall structures.The motion characteristic of a vertical damping system is that every mass has horizontal and rotational displacements simultaneously.The establishment of dynamic equations should take into account the equilibrium conditions of both horizontal and rotational vibrations.Dynamic equilibrium equations of VID systems are derived from a model of a structure with VID.An example shear-wall structure, with and without VID, is studied.There are some changes in the characteristics of the maximum horizontal displacement response.Without dampers, the relative displacements between different floors in the shear wall increase with height.With dampers, the relative displacements are more uniformly distributed, and lateral displacements at the top and at the bottom are closer.When the damping coefficient is 1 000 kN s/m, the numerical results reveal that the maximum horizontal displacement and the maximum rotational displacement of the top floor have reduced by 59.3% and 54.8% respectively.

     

  • loading
  • Aksogan, O., Arslan, H. M., Choo, B. S., 2003. Forced Vibration Analysis of Stiffened Coupled Shear Walls Using Continuous Connection Method. Engineering Structures, 25(4): 499-506 doi: 10.1016/S0141-0296(02)00192-X
    Lee, D. G., Kim, H. S., Chun, M. H., 2002. Efficient Seismic Analysis of High-Rise Building Structures with the Effects of Floor Slabs. Engineering Structures, 24 (5): 613-623 doi: 10.1016/S0141-0296(01)00126-2
    Madsen, L. P. B., Thambiratnam, D. P., Perera, N. J., 2003. Seismic Response of Building Structures with Dampers in Shear Walls. Computers and Structures, 81 (4): 239-253 doi: 10.1016/S0045-7949(02)00441-8
    Marko, J., Thambiratnam, D. P., Perera, N. J., 2004. Influence of Damping Systems on Building Structures Subject to Seismic Effects. Engineering Structures, 26(13): 1939-1956 doi: 10.1016/j.engstruct.2004.07.008
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(9)  / Tables(3)

    Article Metrics

    Article views(866) PDF downloads(18) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return